KEANDALAN BANGUNAN GEDUNG PASAR RAKYAT TEMATIK WISATA UBUD

TJOKORDA ISTRI PRAGANINGRUM, NI LUH MADE AYU MIRAYANI PRADNYADARI, NI NYOMAN INTAN SAWITRI SARASWATI

Abstract


Implementing building reliability is necessary to ensure the safety of all elements in the building. The Ubud Tourism Thematic People's Market is a 2-story building equipped with a basement. Located on Jl. Raya Ubud Nomer. 35, Ubud District, Gianyar, with a building area of 8,253 m2. This research aims to determine the level of reliability of the Ubud Thematic Tourism People's Market building. This research uses quantitative descriptive research methods. Data was obtained from a questionnaire guided by Minister of Public Works Regulation No. 29/PRT/M/2006 and Gianyar Regent Regulation Number 7 of 2023. Data analysis in this research was carried out using interview method and questionnaires. The interview method used purposive sampling with a sample of parties involved in the construction of the Ubud Thematic Tourism People's Market building, with a total of 26 respondents. The results obtained by the level of reliability of the Ubud Thematic Tourism People's Market building were divided into five, namely architectural reliability of 96.08% including reliable (95 - 100%), structural reliability of 95.92% including reliable (95 - 100%), reliability of utilities and fire protection is 96.25% including reliable (95 – 100%), reliability of accessibility is 95.76% including reliable (95 – 100%), and reliability of building layout and environment is 95.4% including reliable (95 – 100% ). The total reliability value of the Ubud Thematic Tourism People's Market building is 96.80%, including reliability (95 – 100%).

Keywords


Reliability, Building, Market, Building

Full Text:

PDF

References


Kusumaningrat, K. C. (2022). Jelang Liburan Akhir Tahun, Ubud Bali Ramai Dikunjungi Wisatawan Mancanegara

Nurhayati. (2010). Manajemen Proyek. Penerbit: Graha Ilmu, Yogyakarta.

Peraturan Bupati Gianyar Nomor 7 Tahun 2023. Rencana Detail Tata Ruang Kecamatan Ubud Tahun 2023-2043.

Peraturan Menteri Pekerjaan Umum Nomor 29/PRT/2006. Pedoman Persyaratan Teknis Bangunan Gedung.

Peraturan Pemerintah No. 36 Tahun 2005 tentang Peraturan Pelaksanaan Undang Undang No. 28 Tahun 2002 tentang Bangunan Gedung

Praganingrum, T. I., Pradnyadari, N. L. M. A. M., Firanthi, P. O. M. (2022). Analisis Keandalan Bangunan Gedung (Studi Kasus: Bangunan Gedung Rektorat Universitas Mahasaraswati Denpasar. Jurnal Ganec Swara Vol. 17, No. 1, Maret 2023.

Priyo, M., & Sujatmiko, I. H. (2011). Evaluasi Keandalan Fisik Bangunan Gedung, Studi Kasus di Wilayah Kabupaten Sleman. Semesta Teknika, Seleman.

Undang-Undang Republik Indonesia No. 28 Tahun 2002 tentang Bangunan Gedung.




DOI: https://doi.org/10.35327/gara.v17i4.650

Refbacks

  • There are currently no refbacks.


Copyright (c) 2023 GANEC SWARA

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

TERINDEKS

 

 

 

 

 

 

 


_______________________________

Ganec Swara

Published by UNMAS Denpasar K. Mataram |
Email: ganecswara@gmail com; aminullahmtk@gmail.com

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

    
Stat Pengunjung GARA